Measurement of macular pigment: Raman spectroscopy versus heterochromatic flicker photometry

Neelam, K. and O'Gorman, N. and Nolan, John M and O'Donovan, O. M. and Wong, H. B. and Eong, K. G. A. and Beatty, Stephen (2005) Measurement of macular pigment: Raman spectroscopy versus heterochromatic flicker photometry. Investigative Opthalmology & Visual Science, 46 (3). pp. 1023-1032. ISSN 1552-5783

Full text not available from this repository.

Abstract

PURPOSE. There are several techniques for measuring macular pigment (MP) in vivo, of which Raman spectroscopy (RS) is a recently developed objective method. This study reports the reproducibility, test-retest variability, and validity of RS MP readings, by comparing them with heterochromatic flicker photometry (HFP). METHODS. MP was measured with HFP and RS in 120 healthy subjects, and the latter technique was also used on two separate occasions in a sample of 20 subjects to investigate the intersessional variability of readings. Intrasessional reproducibility of RS MP measurements was also calculated. In addition, serum concentrations of lutein (L) and zeaxanthin (Z) were measured and correlated with both RS and HFP NIP readings. RESULTS. Mean (+/-SD) NIP in the right eye was 0.279 +/- 0.145 and 0.319 +/- 0.155 with RS and HFP, respectively. The differences between corresponding MP readings taken on RS and HFP lay within the Bland-Altman 95% limits of agreement for the two instruments in 93.6% and 94.4% of cases in the right and left eyes, respectively. Intrasessional reproducibility of RS readings, expressed as the coefficient of variation, was 8.42% +/- 7.12%. Ninety-five percent of MP readings taken with RS on two separate occasions lay within the 95% limits of agreement for the two sessions. A positive, but insignificant, relationship was observed between RS and HFP MP readings and serum concentrations of L and Z (RS, P = 0.356; HFP, P = 0.540). CONCLUSIONS. RS, an objective method of measuring NIP levels in vivo, exhibits acceptable reproducibility and test-retest variability. The results demonstrated good correlation between RS and HFP measurements of MP, thus authenticating RS against a validated psychophysical technique of measuring MP. However, investigators should use only one of these instruments for the duration of any given study because of differences in the scientific rationale, and the factors that influence RS and HFP measurements of MP.

Item Type: Article
Additional Information: ISI Document Delivery No.: 900LR English Article 0146-0404
Uncontrolled Keywords: Optical-density human retina spatial-distribution carotenoid-pigments oxidative stress age degeneration lutein reflectometry population
Departments or Groups: Macular Pigment Research Group
Divisions: School of Science > Department of Chemical and Life Sciences
Date Deposited: 15 Nov 2007 20:31
Last Modified: 22 Aug 2016 10:25
URI: http://repository-testing.wit.ie/id/eprint/60

Actions (login required)

View Item View Item